Three-phase PMSM Comparison between DTC and MPTC

Read full text
Authors: Saif Talal Bahar, Falah Y. H. Ahmed
Cited by: 1
References: 12

Abstract

This paper compares the control performance, average switching frequency, and parameter robustness of a Direct Torque Control (DTC) system and a Predictive Torque Control (MPTC) system based on the stator magnetic flux coordinate system of a permanent magnet synchronous motor (PMSM). The DTC system has a simpler architecture and a lower average switching frequency, but its magnetic flux and torque ripple are larger than those of the MPTC system. The MPTC system outperforms the DTC system in terms of performance.

Fields of Study & Subjects

Sensorless Control of Electric Motors Control Systems in Engineering Magnetic Bearings and Levitation Dynamics

Publication details

Journal / source
Edison journal for electrical and electronics engineering.
Publisher
Sumerian Scriptum Synthesis Publisher
Pages
9–15
Publication date
11 July 2026