Comparative evaluation of EPI and SWI for the assessment of PRL and CVS in Multiple Sclerosis
Abstract
Abstract Introduction The 2024 McDonald criteria incorporate the central vein sign (CVS) and paramagnetic rim lesions (PRL) as supportive imaging biomarkers for MS diagnosis. While susceptibility-weighted-imaging (SWI) and T2*-weighted echo-planar-imaging (EPI) are generally used to assess CVS/PRL, their relative performance remains unclear. This study compared high-resolution isotropic-T2*-EPI with non-isotropic SWI for CVS/PRL detection. Materials and Methods In this multi-centre study, 21 patients with MS underwent harmonized 3T-MRI including EPI and SWI. CVS and PRL were evaluated according to NAIMS criteria. Whole-brain and controlled lesion analyses on 120 pre-selected lesions were performed independently for each contrast, with EPI serving as reference standard. Results In whole-brain analyses, SWI showed good sensitivity for CVS eligibility and positivity (AC1=0.68-0.78) but significant directional disagreement with EPI (p
Fields of Study & Subjects
Multiple Sclerosis Research Studies
Advanced MRI Techniques and Applications
Advanced Neuroimaging Techniques and Applications
Publication details
- Journal / source
- medRxiv
- Publication date
- 9 February 2026
- Language
- EN
- Document type
- Preprint