A cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets
Abstract
ABSTRACT Objective Many deep brain stimulation (DBS) systems sense local field potentials (LFPs) for patient monitoring or closed-loop therapy (CL-DBS). LFPs can be impacted by artifacts, including a recently discovered cardiac non-electrocardiographic pulse signal that can be visually masked by commercial device filters. We aimed to establish its prevalence across patient groups and brain areas, and to investigate its spectral impact. Methods We performed a cross-sectional analysis of LFPs recorded from the cranially mounted Picostim from the pedunculopontine nucleus in multiple systems atrophy patients, periacqueductal gray and sensory thalamus in chronic pain patients, and the centromedian thalamic nucleus (CMT) in paediatric epilepsy patients. For comparison, we analyse externalised recordings from the subthalamic nucleus in Parkinson’s disease patients. The PulsAr algorithm was developed to detect and extract pulsatile signals, and we characterised contamination level and spectral content. Results Though not visually obvious in CMT, the pulsatile signal was algorithmically detected in all targets, with 33% of LFPs across targets classed as contaminated. Pulse signal power was similar across targets and may have been masked by higher endogenous activity in CMT. While its dominant frequencies were in the heartbeat range, the signal had spectral content extending up to >10Hz. Conclusions A heart pulse signal affects LFP recordings from DBS leads across brain regions and patient groups. While masked by some device filters, spectral content can extend into higher (clinically relevant) frequencies. Researchers and clinicians should exercise caution when sensing lower LFP frequencies, especially for automated control of therapy in CL-DBS. Highlights Historically, electrocardiographic artifacts have been a major source of artifact affecting deep brain stimulation recordings, however pulsatile artifact is less well described. A cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets. We introduce an ECG-independent algorithm that detects and extracts this pulsatile signal. The heart pulse signal looks like the intracranial pressure waveform and affects spectral frequencies above the heart rate range up to >10Hz. Clinicians should incorporate screening and procedures to ensure accurate biomarker detection for clinical decision making.
Fields of Study & Subjects
Neurological disorders and treatments
Obsessive-Compulsive Spectrum Disorders
Vagus Nerve Stimulation Research
Publication details
- Journal / source
- bioRxiv (Cold Spring Harbor Laboratory)
- Publication date
- 11 February 2026
- Language
- EN
- Document type
- Preprint