Transient Magnetic Resonance Elastography: a method to measure the mechanics of the active heart

Read full text
Authors: Marco Barbero Mota, Giacomo Annio, Guillaume Rucher, Jordi Martorell
Cited by: 0
References: 23

Abstract

ABSTRACT Myocaridum biomechanics are a biomarker for multiple cardiac pathologies. However the rapid and complex heart motion hampers accurate measurements of the tissue stiffness. Current in vivo methods for the evaluation of myocardium mechanical health are either highly invasive or can only provide with a global surrogate of heart function as they suffer from poor spatiotemporal resolution. We propose a new in vivo technique, transient magnetic resonance elastography (tMRE), to assess the dynamic cardiac biomechanics. tMRE is able to quantify local shear wave speed as a proxy for myocardial stiffness at user-defined times within the cardiac cycle. We report proof-of-concept results where we probe the septum of 4 different healthy rat specimens at 3 physiologically distinct cardiac phases. We provide with apparent speed measurements for early systole, mid-late systole and early diastole that match the expected values from the cardiac cycle physiological mechanics. We correct for non-negligible geometrical biases using literature results and report true stiffness values where possible. Finally, we validate tMRE in phantom experiments.

Fields of Study & Subjects

Ultrasound Imaging and Elastography Advanced MRI Techniques and Applications Cardiovascular Function and Risk Factors

Publication details

Journal / source
bioRxiv (Cold Spring Harbor Laboratory)
Publication date
4 March 2026
Language
EN
Document type