A Reproducible Pipeline for Processing Commercial Wearable Step-Count Data in Aging Cohorts: Application and Evaluation in the STRRIDE-PD Reunion Study
Abstract
Abstract Wearable devices offer the ability to objectively characterize free-living physical activity; however, raw step-count data generated by commercial devices require systematic processing before they can support rigorous inference. We describe a transparent, reproducible standard operating procedure (SOP) for transforming epoch-level step-count data from commercial Garmin devices into participant-level analytic variables and demonstrate its application in the STRRIDE-PD Reunion study: a long-term follow-up of older adults originally enrolled in a supervised exercise intervention trial. This data pipeline standardizes timestamps, reconstructs daily epoch grids, infers wear time from observed step patterns, and applies a prespecified valid-day threshold (≥10 hours inferred wear time) to generate participant-level summaries. Among 67 participants (mean age 71.4 years, 65.7% women), the median valid-day count was 10 days, median average daily steps were 5,794, and participant-level estimates were identical across ≥10-hour and ≥6-hour valid-day thresholds. Wearable-derived step counts were significantly associated with 9 of 16 cardiometabolic and fitness outcomes, including cardiorespiratory fitness, body composition, and lipid profiles. By contrast, self-reported exercise – assessed via a frequency-by-duration composite ranked into deciles – was not significantly associated with any outcome. A regression calibration framework applied to the full sample quantified the attenuation underlying this discrepancy: the naive self-report model systematically underestimated associations relative to both the observed Garmin model and calibration-corrected estimates. These findings demonstrate that measurement approach is a determinant of scientific conclusions in physical activity research, and that reproducible wearable data pipelines are essential infrastructure for aging epidemiology. Highlights A reproducible standard operating procedure processed Garmin step-count data without wear-time indicators. Wearable steps predicted 9 of 16 outcomes; self-reported exercise predicted none. Regression calibration revealed that self-report systematically underestimated physical activity-health associations. Measurement approach determines physical activity-health conclusions in aging cohort research.
Fields of Study & Subjects
Physical Activity and Health
Cardiovascular and exercise physiology
Context-Aware Activity Recognition Systems
Publication details
- Journal / source
- medRxiv
- Publisher
- openRxiv
- Publication date
- 19 May 2026
- Language
- EN
- Document type
- Preprint