Procedural Comparison of the Amulet Versus Watchman Devices: A Single Center’s 'Change of Heart'

Read full text
Authors: Marc T Zughaib, Andrew Sherman, Wadie S. David, Keyur Patel, Brandon Grodman, Marcel Zughaib, Christopher Bradley
Cited by: 0
References: 18

Abstract

Background The recommendation level for left atrial appendage occlusion (LAAO) via device implantation has increased in the most recent American College of Cardiology (ACC) guidelines, resulting in an increase in implantation rates. Our center had the unique experience of originally implanting Watchman deviceTM (Boston Scientific, Marlborough, MA, US) devices from 2017 to 2021 and abruptly switching to implanting Amplatzer AmuletTM (Abbott Cardiovascular, Plymouth, MN, USA) devices from 2021 to the current day. This sudden switch between devices created a unique opportunity for direct comparisons of the two LAAO devices. Our study aimed to compare the differences between these two devices regarding procedural time, radiation dose, and contrast use. Methods Several patients (n=1262) underwent LAAO implantations from 2017-2024 at our center. We performed simple random sampling to select 200 patients that received the Watchman devices and 200 patients that received the Amulet devices. Demographic information, procedural time, radiation dose, and contrast doses were collected for all of them. Student’s t-tests were performed on continuous variables for statistical analyses. Results The average procedure time overall was 56.71 minutes. The average radiation dose of patients undergoing the Watchman device implantation was 167.5 mGy (95% CI: 140.9-194.1) and 247.0 mGy (95% CI: 201.4-286.7) for the Amulet device (p=0.001). The average procedure time did not differ as it was 52.4 minutes (95% CI: 48.7-56.1) for the Watchman device implantation versus 56.1 minutes for the Amulet implants (95% CI: 52.1-60.1; p=0.183). The average contrast dose also did not differ, as patients undergoing the Watchman device implantation used 31.3 cc (95% CI: 27.8-34.8), whereas it was 34.5 cc (95% CI: 31.4-37.7; p=0.176) with the Amulet device. Conclusion There was a significantly higher radiation dose associated with the implantation of the Amulet versus the Watchman devices. There were no significant differences between procedural time or contrast use between the two devices.

Fields of Study & Subjects

Atrial Fibrillation Management and Outcomes Cardiac Arrhythmias and Treatments Cardiovascular and Diving-Related Complications

Publication details

Journal / source
Cureus
Volume
18
Issue
2
Pages
e103404–e103404
Publication date
11 February 2026
Language
EN