Design and Experimental Evaluation of an Ultrasonic Generator for the Inactivation of Gram-positive and Gram-negative Bacteria
Abstract
This research presents the design and experimental application of an ultrasonic generator based on an IC 555 timer as a source of ultrasonic waves for bacterial inactivation. The developed system operated in the frequency range of 40–65 kHz and was experimentally evaluated using Gram-positive and Gram-negative bacterial suspensions with fixed initial concentrations. The Gram-positive bacterium used in this study was Staphylococcus aureus, while the Gram-negative bacterium was Escherichia coli.Bacterial samples were exposed to ultrasonic radiation at various frequencies and irradiation distances for a fixed irradiation time of 10 minutes. The effectiveness of ultrasonic treatment was evaluated based on bacterial mortality percentage and average bacterial reduction (CFU/mL). The results show that bacterial mortality increases with increasing ultrasonic frequency for both Gram-positive and Gram-negative bacteria. Under identical irradiation conditions, Gram-negative bacteria consistently exhibited higher mortality than Gram-positive bacteria. In addition, shorter irradiation distances resulted in higher bacterial inactivation efficiency for both bacterial groups.
Fields of Study & Subjects
Microbial Inactivation Methods
Ultrasound and Hyperthermia Applications
Ultrasound and Cavitation Phenomena
Publication details
- Journal / source
- Asian Journal of Research and Reviews in Physics
- Volume
- 10
- Issue
- 1
- Pages
- 26–34
- Publication date
- 6 February 2026
- Language
- EN