Common Iron Passive Magnetic Shielding for Scintillator Array Photomultiplier Tubes

Read full text
Authors: T. Atovullaev, S. Cherepanov, A. Atovullaeva, J. Kahlbow, M. Patsyuk, O. Hen, G. Johansson, I. Kruglova, B. Meirovich, S. Nepochatykh, E. Piasetzky, S. Piyadin
+4 more A. Salamatin, S. Sedykh, S. Segev, Y. P. Zhang
Cited by: 0

Abstract

In accelerator-based experiments, detector arrays constructed from organic plastic scintillators are widely used for measurements of particle timing, hit position, and energy loss. These detectors are often operated in proximity to magnetic spectrometers, where the associated photomultiplier tubes (PMTs) are exposed to fringe magnetic fields. The standard approach to mitigate magnetic interference involves individually shielding each PMT. In this work, we present a combined passive shielding solution consisting of a common iron enclosure for a row of PMTs, supplemented with individual mu-metal cylinders. This configuration was deployed during a 2022 experiment at JINR. Performance evaluations show that the proposed shielding effectively preserves PMT gain and timing resolution, demonstrating its viability for future applications in similar experimental environments.

Fields of Study & Subjects

Radiation Detection and Scintillator Technologies Atomic and Subatomic Physics Research Neutrino Physics Research

Publication details

Journal / source
arXiv (Cornell University)
Publication date
4 January 2026
Document type