Conduction system pacing vs. biventricular pacing for cardiac resynchronization
Abstract
Aims: There are limited prospective randomized studies comparing left bundle branch area pacing (LBBAP) and biventricular (BiV) pacing for cardiac resynchronization therapy (CRT). The study tested whether LBBAP is non-inferior to BiV pacing in patients with Class I indication for CRT. Methods and results: The CSP-SYNC study is an investigator-initiated, randomized, single-centre study. Sixty-two patients were randomized 1:1 to LBBAP or BiV. The primary study endpoint was the change in left ventricular ejection fraction (LVEF) at 6 months. Secondary endpoints included changes in echo and clinical parameters after 6 months and 12 months. Thirty-one patients were randomized to each arm. Most patients were males (71%), and 32% had ischaemic cardiomyopathy. At 6 months, similar improvement of LVEF was observed in the LBBAP group compared to the BiV group [14.0% (95% confidence interval (CI): 11.2–16.8) in LBBAP vs. 8.5% (95% CI: 5.6–11.2) in BiV] with a mean intergroup difference of 5.6% (95% CI: 1.6–9.5
Fields of Study & Subjects
Cardiac pacing and defibrillation studies
ECG Monitoring and Analysis
Cardiac electrophysiology and arrhythmias
Publication details
- Journal / source
- DiRROS repository (University of Maribor)
- Publication date
- 5 January 2026
- Language
- EN