Inter-Rater Reliability of Manual Waist Circumference and Agreement With DXA-Derived Waist in Male Collegiate Rugby Players

Authors: Hayden Johnson, Christian Moncayo Rivera, Stephanie Hansford, Regan Renfro, Dalton Prye, Matthew Poole, Saheed Jaiyeola, Sage A Newman, Adesiji Adetona, Oscar Woodside, J. B. Hughes, Preston James
+5 more Kelly Hines, Jade Simon, Drew Edward Gonzalez, Christopher D. Greenleaf, Mike Spillane
Cited by: 0

Abstract

Waist circumference (WC) is a low-cost surrogate of central adiposity, but measurement error can limit athlete monitoring. PURPOSE: Evaluate inter-rater reliability of manual WC and agreement with dual-energy X-ray absorptiometry (DXA)-derived WC in male collegiate rugby players. METHODS: Twenty-one male collegiate rugby players completed baseline testing (manual WC and DXA completed same day) following an overnight fast and euhydration. Two trained raters independently measured WC on bare skin at the superior border of the iliac crest (site not pre-marked) using a seca 201 measurement tape, with participants standing feet together and arms relaxed at their sides; the tape was verified horizontal/level around the trunk and measurements were recorded to the nearest 0.1 in following a standardized breathing cue after a normal expiration. Each rater obtained one measurement and was blinded to the other rater's value. Whole-body DXA (Hologic Horizon W; APEX v5.6.1.3 rev 007) generated automated WC and visceral adipose tissue (VAT) estimates. Inter-rater reliability was assessed using ICC (2,1), standard error of measurement (SEM), minimal detectable change (MDC95), paired t-test, and Bland-Altman analysis. Agreement between mean manual WC and DXA WC was evaluated with Pearson correlation and Bland-Altman. RESULTS: Manual WC was 35.5 ± 5.8 in (Rater A) and 35.6 ± 6.0 in (Rater B) with trivial bias (-0.05 ± 0.46 in; p=0.60). Inter-rater reliability was excellent (ICC=0.997; SEM=0.32 in; MDC95=0.88 in) with limits of agreement -0.96 to 0.85 in. DXA WC was 38.4 ± 6.8 in and correlated strongly with manual WC (r=0.969, p CONCLUSION: Manual WC demonstrates near-perfect inter-rater reliability in male collegiate rugby players and is suitable for longitudinal monitoring when standardized. However, DXA- and tape-derived WC are not interchangeable due to systematic bias; consistent methodology is recommended when tracking central adiposity.

Fields of Study & Subjects

Body Composition Measurement Techniques Reliability and Agreement in Measurement Sports Performance and Training

Publication details

Journal / source
TopSCHOLAR (Western Kentucky University)
Publication date
21 February 2026