Thin-wall systems, consisting of two precast concrete shells connected by lattice girders, have become increasingly popular in modern construction due to their efficiency and structural reliability. After installation, the cavity between the shells is filled with fresh concrete to form a continuous cross-section. This approach eliminates most on-site formwork, accelerates construction, and can improve costeffectiveness and site safety. However, a proper execution of the concrete–concrete interface is critical because it is concealed behind the shells. Delamination at this interface may compromise composite action, raising concerns about shear transfer and stability. This study investigates the role of lattice girders in ensuring structural performance under such conditions. First, the shear transfer capacity was verified according to four design standards: EN 1992- 1-1 (CEN, 2005), Model Code 2010 (fib, 2010), EN 1992-1-1:2023 (CEN, 2023), and Model Code 2020 (fib, 2024). For the considered case, lattice girders were found to provide sufficient capacity to transfer interface shear forces, indicating that delamination does not pose a structural risk. Nevertheless, notable differences between standards were observed, and for one lattice girder, EN 1992-1-1:2023 (CEN, 2023) under unfavourable assumptions suggested insufficient capacity, highlighting the benefit of using double lattice girders. Secondly, buckling behaviour of the outer shell supported by lattice girders was analysed using the theory of a beam on an elastic foundation. Results show that the critical buckling load decreases with increasing gap width between the shell and the in-situ concrete. However, gaps up to 0.10 m for one lattice girder and 0.12 m for a double lattice girder remain non-critical. Even gaps as large as 0.50 m maintain buckling resistance above the shell’s compressive capacity, confirming that incorporating thermal insulation between the shells is structurally feasible without compromising safety.

Fields of Study & Subjects

Structural Behavior of Reinforced Concrete Structural Load-Bearing Analysis Construction Engineering and Safety

Publication details

Journal / source
Lirias
Publication date
15 June 2026
Language
EN