FROST-FREE AIR-SOURCE HEAT PUMPS FOR SUSTAINABLE HEATING IN COLD CLIMATES

Summarise with VIRAT
Authors: Siddhartha Gollamudi
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Emissions from building heating systems account for 11% of global greenhouse gas (GHG) emissions. Replacing fossil-fuel-based heating systems with electricity-powered air-source heat pumps (ASHPs) can substantially reduce GHG emissions, particularly in regions where electricity is generated from low-emission sources. ASHPs can extract thermal energy from the ambient air and deliver it indoors, while operating at coefficients of performance (COP) of 1.5 to 3.0. However, ASHP performance is plagued by frosting and high refrigerant discharge temperatures in cold climates. Frosting is a phenomenon where moisture in the ambient air freezes on the outdoor unit (i.e., the evaporator) of an ASHP. In this thesis, the impacts of frosting and high discharge temperatures are evaluated in 45 Canadian cities. It is found that frosting is the major problem in the most populous regions of Canada with large conditioned floor space, and that frosting can increase energy consumption of ASHPs by up to 35%. To prevent frosting, this thesis proposes a liquid-to-air membrane energy exchanger (LAMEE) integrated with an ASHP to create a frost-free air-source heat pump called the LAMEE-HP. LAMEEs can simultaneously cool and dry air, thereby lowering the dew point temperature of the air flowing through the LAMEE. If the dew point is sufficiently reduced, frosting can be prevented. In a LAMEE-HP, the LAMEE serves as the outdoor unit instead of a traditional sensible-only evaporator to help reduce or prevent frosting. To evaluate the performance of a LAMEE HP, an analytical model called the coupled 𝜖-NTU method is developed and assessed for estimating heat and mass transfer rates in a LAMEE. Frosting limits for LAMEEs are defined to understand the conditions under which a LAMEE would remain frost-free. The main contribution of this thesis is a conceptual proof supported by numerical evidence that a LAMEE-HP can operate without frosting under any climatic condition when appropriately designed. The LAMEE-HP can also humidify indoor spaces. Simulation results in the thesis show that a LAMEE HP has, on average, a 50% higher COP than a standard ASHP under typical conditions that lead to frosting, i.e., at outdoor air temperatures between 5°C and -15°C. Annual energy savings from using a LAMEE-HP compared to a standard ASHP ranged from 12% in Saskatoon to 28% in Toronto and 35% in Vancouver, suggesting that LAMEE-HPs can reduce GHG emissions and heating costs in cold climates.

Fields of Study & Subjects

Refrigeration and Air Conditioning Technologies Adsorption and Cooling Systems Building Energy and Comfort Optimization

Publication details

Journal / source
HARVEST (University of Saskatchewan)
Publication date
1 January 2026
Language
EN
Document type
Thesis