Strength analysis of rebuilt windows in historical buildings by the FE-method

Read full text Summarise with VIRAT
Authors: Zuha Badawi Alshaar
Cited by: 0
References: 2

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The Machine and Assembly Hall in Varvsstaden (Malmö, Sweden) is a heritage industrial building currently being refurbished into office space. As part of the renovation, the historic cast-iron framed windows will be complemented by an inner insulating window installed approximately 500 mm inside the existing line, creating an air cavity and altering the mechanical loading conditions of the original system. This thesis evaluates whether the historic windows can withstand the modified load situation while meeting preservation requirements. Finite element analyses were performed in Abaqus using measured window geometries and material properties from literature. Wind loading, thermally induced cavity pressure, and atmospheric pressure variations were analyzed individually and in combination for outdoor temperatures between −20 °C and +34 °C. Responses were compared for small and large windows before and after retrofit, supported by mesh convergence studies. After renovation, the inner window increased stiffness and reduced wind-induced deflection, but the assumed sealed cavity introduced pressure-driven load cases that became critical under cold outdoor conditions. The small window developed higher local glass stresses near supported edges and corners, while the large window showed greater global deflection due to its larger span. Frame stresses remained below conservative reference values for cast iron, whereas glass stresses in most post-retrofit combinations exceeded the adopted screening threshold. Overall, the retrofit improves serviceability under wind loading but may increase the risk of glass distress in cold scenarios due to cavity-pressure effects. Controlled cavity pressure equalization (ventilation) is therefore recommended to reduce pressure-induced demand on the historic glazing.

Fields of Study & Subjects

Masonry and Concrete Structural Analysis Structural Analysis of Composite Materials Building energy efficiency and sustainability

Publication details

Journal / source
Lund University Publications Student Papers (Lund University)
Publication date
1 January 2026
Language
EN
Document type
Thesis