Ultrahigh Resolution Imaging with k-Space Weighting during and after Acquisition

Summarise with VIRAT
Authors: R. Pohmann, K. Scheffler
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Introduction: The spatial resolution in MRI is mainly restricted by the SNR, which often demands heavy averaging to obtain an acceptable image quality. Acquisition weighting, routinely used in chemical shift imaging [1-4], is a technique that allows to increase SNR and suppress ringing artifacts by modulating the number of averages depending on k-space position, yielding improved images without increasing scan time as long as averaging is necessary anyway to improve SNR. Here, acquisition weighting is combined with retrospective weighting in read direction, using a SNR-optimized weighting function. Methods: An acquisition-weighted FLASH sequence was implemented on a 14.1 T Bruker MRI scanner, allowing varying numbers of averages depending on k-space position in both phase encoding direction. Simulations show a potential SNR improvement of almost a factor of 2 (94 %). As no k-space weighting during acquisition is possible in read direction, this dimension was filtered retrospectively with an optimized weighting function w(k): A generalized Hamming function w(k) = γ + (1-γ)·cos(2π|k|/K) with k: k-space position and K: total k-space range was found SNR-optimal for γ = 0.65, yielding in a theoretical SNR gain of 16 % for the read weighting only. Demonstration images were acquired on a ex vivo rat brain, before applying this technique to acquire ultra high resolution images of a pig brain slice. Results/Discussion: Images of the rat brain with a standard unweighted FLASH sequence with a matrix size of 256 × 192 × 32, a spatial resolution of 125 μm and four averages and the weighted acquisition with similar resolution and equal scan duration are shown in Fig. 1, together with the weighting function and the spatial response function of both techniques to illustrate the voxel sizes. While the size of the acquisition weighted voxels is only slightly larger than that of the unweighted sequence, the SNR is around 70 % higher, while the equivalent resolution can be assessed by the similar visibility of small details in both images. Fig. 2 shows images from a pig brain slice, containing the optic nerves and the optic chiasm, imaged with a spatial resolution of 30 μm over a FOV of 4.52 × 3.07 × 1.15 mm3, with equal voxel size and scan durations in both scans. An 80 % increased SNR for equal spatial resolution and reduced ringing artifacts allows for identification of structures inside the optic nerves. Conclusion: Acquisition weighting is a simple way to improve SNR without losses in scan time or spatial resolution, especially for high resolution imaging when averaging is necessary anyway. Retrospective weighting in the read direction can contribute to the SNR gain, though a careful optimization of the weighting function is necessary to ensure its positive effect. This technique thus can make it possible to acquire images with very high spatial resolutions.

Fields of Study & Subjects

Advanced MRI Techniques and Applications Medical Imaging Techniques and Applications Advanced NMR Techniques and Applications

Publication details

Journal / source
MPG.PuRe (Max Planck Society)
Publication date
1 January 2026
Language
EN