模块化钢框架外套筒焊接连接节点的抗震性能试验研究
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
模块间节点的抗震性能对结构整体安全至关重要。文中提出了一种模块间焊接连接节点(简称WIMJ),通过对3个该类型节点开展往复加载试验,研究了外套筒高度和厚度对节点破坏模式、应力分布、延性耗能等抗震性能的影响,并对节点的刚性特征进行了评估。结果表明:WIMJ的破坏模式为梁端受弯破坏,破坏位置主要集中在梁翼缘与柱的焊接连接处;节点的滞回曲线较为饱满,受力过程依次经历初始滑移、弹性变形、弹塑性变形、破坏四个阶段;其延性系数介于0.75~2.03之间,等效黏滞阻尼系数可达0.15,强度退化系数介于0.85~1.00之间,展现出良好的抗震性能;外套筒高度和厚度对节点峰值承载力与延性变形的影响较小;节点的残余变形曲线呈两阶段变化趋势;WIMJ属于半刚性部分强度连接节点。
Fields of Study & Subjects
Seismic Performance and Analysis
Structural Load-Bearing Analysis
Structural Response to Dynamic Loads
Publication details
- Journal / source
- DOAJ (DOAJ: Directory of Open Access Journals)
- Publication date
- 1 March 2026
- Language
- ZH