Не опубліковано: РОЗРОБКА ШВИДКОГО, ПРОСТОГО ТА НЕДОРОГОГО ТЕСТУ ДЛЯ ВИЗНАЧЕННЯ ВМІСТУ ЗАЛІЗА В ПОВЕРХНЕВИХ І МОРСЬКИХ ВОДАХ

Read full text Summarise with VIRAT
Authors: Марта Ігорівна Літинська, Марія Олександрівна Дубенець, Світлана Олександрівна Кирій
Cited by: 0
References: 41

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Military operations in Ukraine have intensified the challenge of monitoring water bodies and have created a strong demand for a rapid, simple, and low-cost method for iron screening under limited laboratory control. The object of research is an indicator colorimetric test system intended for fast determination of iron concentration in surface and marine waters under field conditions. To select the test formulation, two chromogenic reagents, potassium thiocyanate (KSCN) and sulfosalicylic acid, as well as pH adjusters, 10% NH4OH and 5N H2SO4, were compared using spectrophotometric characteristics in model waters containing 1 and 5 mg/L of Fe(III). It was established that, at both iron levels, the KSCN and H2SO4 combination provides the highest color intensity and the best visual contrast. The sulfosalicylic acid system produces a less contrasted signal, and the yellow shades formed in alkaline medium are difficult to distinguish reliably by visual inspection and therefore complicate detection. The thiocyanate complex was shown to be sufficiently stable for field readout since during the first 10 minutes after mixing the absorbance decreases by less than 5% and the change is not visually perceptible. A color scale covering 0 to 10 mg/L of Fe(III) was developed together with a test protocol that involves adding 25 ml of the sample, 2.5 ml of 5N H2SO4, and 1 g of KSCN, followed by reading after approximately 2 minutes by comparing the solution color with the scale. The developed test systems are recommended for rapid monitoring of iron in natural waters. The kit can be implemented in a “cylinder – ampoule – sachet – scale configuration”, which reduces reagent dosing steps and supports use outside the laboratory. Results can be documented using smartphone photography followed by RGB based color coding.

Fields of Study & Subjects

Water Quality Monitoring and Analysis Environmental and Analytical Chemistry Studies Analytical Chemistry and Sensors

Publication details

Journal / source
Technology audit and production reserves
Volume
3
Publication date
30 March 2026